DVP

The Intelligent Doppler Sensor for Open Channels

The DVP sensor uses Doppler technology to measure the fluid flow velocity of your sewer and stormwater systems.

Its advanced processing and communication capabilities allow the DVP to be transformed into a flowmeter thanks to its own height/surface conversion tables.

It evaluates the signal quality associated with each measurement to provide data of optimal reliability.

Applications

In temporary or permanent metrology, the DVP sensor is used in the following applications:

  • Self-monitoring of networks and sewerage systems
  • Monitoring of flows in irrigation canals, rivers and streams
  • Diagnostic studies
  • Flood prevention and flood control
  • Quantification of industrial discharges
  • Verification of existing flowmeters

Main benefits

  • Measuring Accuracy
  • Possible to measure low velocity and low water levels
  • Diagnosis of the measurement by signal quality
  • Integrated Height/Area tables to calculate the flow rate
  • Height acquisition by external communicating equipment
  • Waterproof
  • Intelligent and reliable digital sensor
  • Direct connection to PLC or data logger
  • Temperature measurement
  • Use in explosive areas

Specifications

  • Bidirectional measurement from 0.01 to 5 m/s
  • Accuracy: ± 2% of the read value for V ≥ 0.5 m/s, ± 0.01 m/s for V < 0.5 m/s
  • Resolution: 1 mm/s
  • Communication: RS232/RS485/SDI-12, Modbus RTU/SDI-12/Modbus protocols, Control mode
  • Data: Velocity/Temperature/Flow/Quality signal and diagnostics
  • External power supply: 9-28 VDC
  • Operating Temperature: -20 to +60 oC (non-frozen fluid)
  • Material: PVDF, polyurethane, stainless steel 316
  • Dimensions: H 19 mm x L 122 mm x W 46 mm
  • Sealing: IP68 / NEMA6
  • Certificates explosive zone: ATEX / IECEX
  • Warranty: 24 months (extendable to 36 months)

Related products

  • MainFlo
  • Intelligens Flow


Related pages

Illustrations

DVP
DVP Strapping
DVP - Field 1
DVP - Field 2
PreviousLevel Measurement by Camera